FlexGRIP Alpha CVC/Arterial

FlexGRIP®

FlexGRIP Alpha CVC/ Arterial is a single use patch, Needle-Free Securement Device to stabilize virtually all suture-winged catheters. Such as central venous catheters (CVC), peripherally inserted catheters (PICC), arterial lines, and hemodialysis catheters.

FlexGRIP Alpha is an Intuitive and High Performing Needle-Free Solution.

 

One size fits all.

 

Features

  • hydrocolloid tape for sensitive skin (CVC / Arterial / Hemodialysis version)
  • “suture-like” flexible posts can be closed/opened
  • tape design enables use of Biopatch
  • Adhesive for additional anchoring of the suture wings

 

Benefits

  • 2 posts replace the need for suturing
  • Prevent catheter migration & related complications
  • Compatible with most catheters with suture wings
  • Designed to prevent MARSI - Medical Adhesive Related Skin Injury
  • Optimal patient comfort, intuitive, fast and easy to use

 

Intended use: The device is used in combination with a compatible catheter, tubing or cable. The device consists of an adhesive dressing and a clamp part to reduce catheter migration and pull out. In combination with a catheter or tubing it is to be used specifically for therapeutic purpose and intended to be used for treatment or alleviation of disease. The bedal catheter stabilization device is a single use device and is attached to the intact skin for a maximum of 7 days.

 

Intended Users:

The device is intended to be used by trained medical professionals in a hospital or clinical setting.

 

Contraindications:

Known hypersensitivity or allergy to hydrocolloid materials or any component of the device.

 

Safety considerations:

Discard if package is damaged.

 

Key points to the Bedal catheter stabilization device usage:

  • Prepare the skin according to the standard hospital protocol for dressing application. Allow the skin to dry completely. Skin prep or hair removal may be required on some patients for better dressing adherence.
  • Remove any residue of the dressing pad with alcohol after removing the device.
  • The extra strip can be used to temporarily secure the catheter during dressing change.
  • Discard after use in appropriate containers for potentially infectious material.

 

Warnings and precautions:

  • Do not use the device where loss of adherence could occur, such as non-adherent skin or confused patient.
  • Always follow the infection control guidelines at your facility.
  • Minimize catheter or cable manipulation during application and removal of the device.
  • The device and the surrounding area should be routinely inspected.
  • Use sterile technique for application and removal of the device.
  • In case of loss or difference in performance, such as loosening of adherence to the skin, the device should be removed and replaced.
  • Read all package insert warnings, precautions and instructions prior to use. Failure to do so may result in severe patient injury.

 

Contact Information

Nexaso Medical Co., Ltd.

47/316 Kaitak Tower, K005010, 5th Floor, Popular Rd, Ban Mai, Pak Kret, Nonthaburi 11120

Tel. 02-0175-766

 

License No. ฆพ.356/2569

 

Are you a healthcare professional?

The information on this page is restricted to healthcare professionals only.

Are you a healthcare professional?

No